Copper-plated steel fibres

PRODUCT PARAMETERS

Copper-plated steel fibres are precision copper-plated on the surface of high-strength steel substrate, which makes the product corrosion-resistant and stretch-resistant, and can significantly enhance the electrical conductivity and mechanical strength of the substrate material, prolonging its service life to meet the industrial demand.
Description
REQUEST A QUOTE

Description

Copper-plated microfilament steel fiber is a fiber made of ultra-fine steel wire plated with copper on the surface and cut and processed. It is straight or bent into a hook shape at both ends.

Copper-plated steel fibres

PRODUCT PARAMETERS:

Length 13mm,Customizable
Diameter 0.1-0.3mm
Tensile strength>2850MPa

Application of Copper-Coated Microfilament Steel Fiber

1. Construction engineering: house construction, prefabricated piles, frame nodes, roof waterproofing, underground waterproofing, etc.

2. Industrial floor: cut-slit floor, no-slit floor, seamless floor, pile-supported floor, garage leveling layer, composite floor slab, raft, factory road, pavement, etc.

3. Pipeline engineering: centrifugal tube, vibration and extrusion tube, pump tube, steel-lined steel fiber concrete pressure tube, etc.

4. Highway bridge engineering: box arch bridge arch ring, continuous box beam, bridge deck, etc.

5. Highway pavement and airport bridge deck engineering: highway pavement, highway pavement in frozen areas, airport pavement, etc.

6. Railway engineering: prestressed railway sleepers, double-block railway sleepers, etc.

7. Water conservancy and hydropower engineering: water flow erosion wear parts, gates, gate canals, ferry canals, dam anti-seepage panels, etc.

8. Port and marine engineering: steel pipe pile anti-corrosion layer, dock facilities, submarine concrete facilities, etc.

9. Other projects: heavy-duty industrial sites/warehouse floors, silos, maintenance and reinforcement projects, underground cables, pipe manhole covers, sewer grates, etc.

Copper-plated steel fibres

Usage of Copper-Coated Microfilament Steel Fiber

Construction technical requirements:

1. The cement grade shall not be lower than 425. The water-cement ratio shall not be greater than 0.5.

2. The diameter length of the coarse aggregate shall not exceed 2/3 of the length of the steel fiber.

3. The volume of steel fiber in steel fiber concrete shall not be less than 0.5%, generally between 0.5-3%, and 1.5%–2.5% is recommended; that is, the dosage range per cubic meter of concrete is: 5-30kg, and 15-25kg is recommended.

4. Sea sand shall not be used for mixing steel fiber concrete, and chloride salt is strictly prohibited.

5. In addition to the above provisions, other materials used in steel fiber concrete shall comply with the provisions on raw materials used in reinforced concrete in the current specifications.

6. The consistency of steel fiber concrete can be determined by referring to the consistency required for ordinary concrete in similar projects. Its slump value can be smaller than the corresponding ordinary concrete requirement.

7. When the steel fiber concrete cushion layer and surface layer with flat-head joint structure has no foundation reinforcement layer such as ash soil under the cushion layer and meets the following conditions at the same time:

a. The thickness of the cushion layer and surface layer before reduction is not more than 130mm.

b. The thickness of the foundation reinforcement layer is greater than the thickness of the cushion layer. Its thickness can be multiplied by the reduction factor 0.75, but shall not be less than 50mm

Copper-plated steel fibres

Material discharge requirements:

Steel fiber and coarse aggregate – stir for 30 seconds – add sand and cement → stir for 30 seconds → add water → stir for 3 minutes

Compacting:

1. When pouring steel fiber concrete, mix and use it as you go, pour continuously, and do not throw away the construction joints until the partition joints are reached. It should be vibrated and compacted during pouring.

2. Surface finishing. Embossed steel fiber concrete has the characteristics of fine coarse aggregate, large sand rate, and random fiber distribution. It is smoothed mechanically to prevent fiber exposure. The embossing process using an embossing machine can also avoid the phenomenon of fiber exposure caused by pulling. After 24 hours, it should be maintained in time according to the routine. It should be covered with straw bags in summer and keep warm in winter.

Packing and Storage
Packing: carton or composite paper bag 25kg/box or bag, 1500kg-2000kg per pallet, also can be produced and packaged according to customer’s requirements.

Company Profile

Cabr-Concrete is the global leader in Low-Density Cellular Concrete (LDCC), Celluar Light Concrete (CLC), and advanced engineered foam solutions. Known globally for its commitment to research, innovation, and applied expertise, we have been providing engineered foam solutions since the early 2012’s.

We can supply Calcium formate over the world. The company has a professional technical department and quality supervision department, a well-equipped laboratory, and equipped with advanced testing equipment and after-sales customer service center.Send us an email or click on the needed products to send an inquiry.

If you want to know more about Polypropylene fibres (PP fibres), please feel free and contact us: sales1@cabr-concrete.com

Payment

T/T, Western Union, Paypal, Credit Card etc.

Shipment

By air, by sea, by express, as customers request.

REQUEST A QUOTE

REQUEST A QUOTE